Contact

RESEARCH METHODS

taVNS Research Protocol and Reporting Checklist

Reproducible taVNS research depends on precise descriptions of the participants, hardware, stimulation protocol, comparator, outcomes, and analysis.

Source review · 19 October 2026 · Educational content

REFERENCE TABLE

Protocol record

DomainMinimum recordReason
ParticipantsEligibility, sample, baseline characteristicsDefines the population studied
DeviceManufacturer, model, firmware or softwareIdentifies the tested system
PlacementEar side, anatomical site, contact arrangementDefines current delivery location
SignalWaveform, frequency, pulse width, amplitudeDefines electrical exposure
ScheduleDuty cycle, session length, repetitionDefines timing and cumulative exposure
ComparatorSham or control setup and maskingDefines the contrast
OutcomesMeasure, time point, analysis planDefines the result
SafetyCollection method, severity, relatedness, withdrawalsDefines event reporting

01

Before enrollment

Record the research question, study design, eligibility criteria, sample-size rationale, intervention, comparator, outcomes, time points, and analysis plan. Trial registration or preregistration preserves the distinction between planned and exploratory analyses.

02

Hardware and stimulation

Identify the device, version, stimulation channel, electrode material and area, ear side, anatomical landmarks, active and reference contacts, waveform, frequency, pulse width, amplitude units, intensity procedure, ramping, duty cycle, session length, and schedule.

Document fitting, contact checks, impedance handling, training, adherence, deviations, and any software used to configure or record sessions.

03

Comparator, masking, and reporting

Describe the sham or control with the same precision as the active condition. Report participant and assessor masking, sensation checks, credibility measures, attrition, exclusions, missing data, adverse events, protocol deviations, and the relationship between registered and reported outcomes.

QUESTIONS

Frequently asked questions

Is a device name enough for replication?

No. Version, electrodes, placement, signal parameters, intensity method, and schedule are also required.

What belongs in a sham description?

Site, signal, sensation, timing, device behavior, masking method, and masking assessment.

Why record protocol deviations?

They show how delivered sessions differed from the planned intervention and help interpret outcomes.